Note
This website is presently under development. The primary website for MOPAC is still http://openmopac.net until the majority of its contents have been migrated here.
CUTOFP
¶
In polymers and solids, a cutoff distance, in Ångstroms, is needed in
order to ensure that every atom has a correct electric environment. If
no cutoff is set, then equivalent atoms would experience different
electric fields. The CUTOFP
distance is set, by default, to 30
Ångstroms. In calculating the potential due to distant atoms, atoms
separated by more than CUTOFP
are treated as if they were at
distance CUTOFP
.
`MOZYME
<mozyme.html>`__ calculations run faster when smaller values
of CUTOFP
are used A suitable value for n.nn is somewhere between
10.0 and 15.0. This will give a large increase in speed. But first, run
a test calculation to verify that the results don’t change much.
When CUTOFP
is less than the default, the number of two-electron
integrals is reduced. This can allow larger systems to be run.